Quality control Fourier transform infrared determination of diazepam in pharmaceuticals.Moros J, Garrigues S, de la Guardia M Department of Analytical Chemistry, University of Valencia, 50 Dr. Moliner Street, 46100 Burjassot, Valencia, Spain. A quality control procedure has been developed for the determination of diazepam in pharmaceuticals using Fourier transform infrared (FTIR) spectroscopy. The method involves the off-line extraction of diazepam with chloroform by sonication and direct determination in the extracts through peak area measurement in the interval between 1672 and 1682 cm(-1) using a baseline correction defined between 1850 and 1524 cm(-1). For standardization it was used an external calibration line established from standard solutions of diazepam in chloroform. The method provides a limit of detection of 0.04 mg per tablet (n=5), a relative standard deviation (R.S.D.) of 0.5% for 5 independent measurements of a standard solution at a concentration level of 0.76 mg g(-1) and a sampling frequency of the whole procedure of 4 h(-1), being required only 45 s for the measurement step. Results obtained by FTIR agree with those obtained by a reference methodology based on ultraviolet spectrometry and thus the developed procedure offers a good alternative for the determination of diazepam in pharmaceuticals. Published 26 February 2007 in J Pharm Biomed Anal, 43(4): 1277-82.